Top 19 Apoptosis Kits for 2020

 

BioVision Annexin V-Cy3 Apoptosis Kit Plus K202-25

BioVision Annexin V-Cy3 Apoptosis Kit Plus, K202-25

BioVision Annexin V-Cy3 Apoptosis Kit Plus, K202-25 - 530 nm) for sytox green dye and fl2 channel for annexin v-cy3 (ex. The assay is based on the observation that soon after initiating apoptosis, cells translocate the membrane phospholipid phosphatidylserine (ps) from the inner face of the plasma membrane to the cell surface. Cy3 shows brighter red fluorescence. The one-step staining procedure takes only 10 minutes. After staining a cell population with annexin v-cy3 and sytox green dye in the provided binding buffer, apoptotic cells show red fluorescence, dead cells show green fluorescence and live cells show little or no fluorescence. Once on the cell surface, ps can easily be detected by staining with a fluorescent conjugate of annexin v, a protein that has a strong natural affinity for ps. ” Detects apoptotic, necrotic & -healthy cells within 10 min detection method- flow cytometry using fl1 channel for sytox green dye (ex = 488 nm -em = 530 nm) and fl2 channel for annexin v-cy3 (ex = 543 nm -em = 570 nm). 570 nm). 543 nm/em. The annexin v-cy3 apoptosis detection kit plus includes annexin v-cy3, sytox green dye, and binding buffer. The sytox green dye is impermeant to live cells and apoptotic cells, but stains necrotic cells with intense green fluorescence by binding to cellular nucleic acids. 488 nm/em. These populations can easily be distinguished by fluorescence microscopy using fitc and rhodamine filters or by flow cytometry using the fl1 channel (ex. Species reactivity- mammaliankit size- convenient sizes (25, 100 and 400 assays)applications- detecting apoptosis in living cells by flow cytometry or fluorescence microscopy. “. In addition, the assay can be directly performed on live cells, without the need of fixation.

 

BioVision Annexin V-EGFP Apoptosis Kit K104-100

BioVision Annexin V-EGFP Apoptosis Kit, K104-100

BioVision Annexin V-EGFP Apoptosis Kit, K104-100 - Egfp is brighter and more photo-stable than other fluorescent reagents. Detection can be analyzed by flow cytometry or by fluorescence microscopy with a fitc filter. The one-step staining procedure takes only 10 minutes. “. -Flow cytometry (ex = 488 nm -em = 530 nm)and fluorescence microscopy -mammalian -25, 100, 400 -applications-detect early/middle stages of apoptosis -differentiate apoptosis from necrosis the annexin v-egfp apoptosis detection kit is based on the observation that soon after initiating apoptosis, most cell types translocate the membrane phospholipid phosphatidylserine (ps) from the inner face of the plasma membrane to the cell surface. Once on the cell surface, ps can be easily detected by staining with an enhanced green fluorescent protein (egfp) fusion of annexin v, a protein that has a strong natural affinity for ps. The kit can differentiate apoptosis vs necrosis when performing both annexin v-egfp and pi staining. In addition, the assay can be directly performed on live cells. ” Detects apoptosis in live cells within 10 min.

 

BioVision Annexin V-Cy5 Apoptosis Kit K103-25

BioVision Annexin V-Cy5 Apoptosis Kit, K103-25

BioVision Annexin V-Cy5 Apoptosis Kit, K103-25 - ” Detects apoptosis within 10 min. Once on the cell surface, ps can be easily detected by staining with a fluorescent conjugate of annexin v, a protein that has a high affinity for ps. Detection method- flow cytometry (ex = 649 nm -em = 670 nm) and fluorescence microscopyspecies reactivity- mammaliankit size- convenient sizes (25, 100, 400 assays) annexin v apoptosis detection kit is based on the observation that soon after initiating apoptosis, cells translocate the membrane phosphatidyl-serine (ps) from the inner face of the plasma membrane to the cell surface. The one-step staining procedure takes only 10 minutes. Detection can be analyzed by flow cytometry or by fluorescence microscopy. “.

 

BioVision Annexin V-PE-Cy5 Apoptosis Detection Kit K129-100

BioVision Annexin V-PE-Cy5 Apoptosis Detection Kit, K129-100

BioVision Annexin V-PE-Cy5 Apoptosis Detection Kit, K129-100 - In addition, the assay can be directly performed on live cells, without the need for fixation. ” Detects apoptosis in live cells within 10 min. The one-step staining procedure takes only 10 minutes. The annexin v-pe-cy5 apoptosis detection kit is based on the observation that soon after initiating apoptosis, most cell types translocate the membrane phospholipid phosphatidylserine (ps) from the inner face of the plasma membrane to the cell surface. Detection method- flow cytometry (ex = 488 nm -em = 670 nm) and fluorescence microscopy species reactivity- mammalian kit size- convenient sizes (25, 100, 400 assays)applications- detect early/middle stages of apoptosis -differentiate apoptosis from necrosis. Results can be analyzed by flow cytometry or fluorescence microscopy. “. Once on the cell surface, ps can be easily detected by staining with a fluorescent conjugate of annexin v, a protein that has a strong natural affinity for ps.

 

BioVision Annexin V-Cy3 Apoptosis Kit Plus K202-400

BioVision Annexin V-Cy3 Apoptosis Kit Plus, K202-400

BioVision Annexin V-Cy3 Apoptosis Kit Plus, K202-400 - After staining a cell population with annexin v-cy3 and sytox green dye in the provided binding buffer, apoptotic cells show red fluorescence, dead cells show green fluorescence and live cells show little or no fluorescence. 530 nm) for sytox green dye and fl2 channel for annexin v-cy3 (ex. Once on the cell surface, ps can easily be detected by staining with a fluorescent conjugate of annexin v, a protein that has a strong natural affinity for ps. These populations can easily be distinguished by fluorescence microscopy using fitc and rhodamine filters or by flow cytometry using the fl1 channel (ex. The assay is based on the observation that soon after initiating apoptosis, cells translocate the membrane phospholipid phosphatidylserine (ps) from the inner face of the plasma membrane to the cell surface. ” Detects apoptotic, necrotic & -healthy cells within 10 min detection method- flow cytometry using fl1 channel for sytox green dye (ex = 488 nm -em = 530 nm) and fl2 channel for annexin v-cy3 (ex = 543 nm -em = 570 nm). The sytox green dye is impermeant to live cells and apoptotic cells, but stains necrotic cells with intense green fluorescence by binding to cellular nucleic acids. “. The annexin v-cy3 apoptosis detection kit plus includes annexin v-cy3, sytox green dye, and binding buffer. 570 nm). Cy3 shows brighter red fluorescence. The one-step staining procedure takes only 10 minutes. 543 nm/em. Species reactivity- mammaliankit size- convenient sizes (25, 100 and 400 assays)applications- detecting apoptosis in living cells by flow cytometry or fluorescence microscopy. In addition, the assay can be directly performed on live cells, without the need of fixation. 488 nm/em.

 

BioVision Annexin V-FITC Apoptosis Kit Plus K201-400

BioVision Annexin V-FITC Apoptosis Kit Plus, K201-400

BioVision Annexin V-FITC Apoptosis Kit Plus, K201-400 - In addition, the assay can be directly performed on live cells, without the need of fixation. These populations can easily be distinguished using a flow cytometry with the 488 nm line of an argon-ion laser for excitation. After staining a cell population with annexin v-fitc and sytox green dye in the provided binding buffer, apoptotic cells show green fluorescence, dead cells show a higher level of green fluorescence and live cells show little or no fluorescence. The sytox green dye is impermeant to live cells and apoptotic cells, but stains necrotic cells with intense green fluorescence by binding to cellular nucleic acids. Both annexin v-fitc and sytox green dye emit green fluorescence that can be detected in the fl1 channel, freeing the other channels for the addition of other probes in multi-color labeling experiments. ” Detects apoptotic, necrotic & -healthy cells within 10 min detection method- flow cytometry (ex = 488 nm -em = 530 nm). The annexin v-fitc apoptosis detection kit plus is based on the observation that soon after initiating apoptosis, most cell types translocate the membrane phospholipid phosphatidylserine (ps) from the inner face of the plasma membrane to the cell surface. Species reactivity- mammaliankit size- convenient sizes (25, 100 and 400 assays)applications- annexin v-fitc kit includes annexin v-fitc for detecting apoptosis and also propidium iodide (pi) for detecting necrosis. “. The annexin v-fitc apoptosis detection kit plus includes annexin v-fitc, sytox green dye, and binding buffer. Once on the cell surface, ps can easily be detected by staining with a fluorescent conjugate of annexin v, a protein that has a strong natural affinity for ps. The one-step staining procedure takes only 10 minutes.

 

BioVision Annexin V-EGFP Apoptosis Kit K104-400

BioVision Annexin V-EGFP Apoptosis Kit, K104-400

BioVision Annexin V-EGFP Apoptosis Kit, K104-400 - Detection can be analyzed by flow cytometry or by fluorescence microscopy with a fitc filter. ” Detects apoptosis in live cells within 10 min. In addition, the assay can be directly performed on live cells. -Flow cytometry (ex = 488 nm -em = 530 nm)and fluorescence microscopy -mammalian -25, 100, 400 -applications-detect early/middle stages of apoptosis -differentiate apoptosis from necrosis the annexin v-egfp apoptosis detection kit is based on the observation that soon after initiating apoptosis, most cell types translocate the membrane phospholipid phosphatidylserine (ps) from the inner face of the plasma membrane to the cell surface. “. Once on the cell surface, ps can be easily detected by staining with an enhanced green fluorescent protein (egfp) fusion of annexin v, a protein that has a strong natural affinity for ps. Egfp is brighter and more photo-stable than other fluorescent reagents. The kit can differentiate apoptosis vs necrosis when performing both annexin v-egfp and pi staining. The one-step staining procedure takes only 10 minutes.

 

BioVision Annexin V-FITC Apoptosis Kit Plus K201-25

BioVision Annexin V-FITC Apoptosis Kit Plus, K201-25

BioVision Annexin V-FITC Apoptosis Kit Plus, K201-25 - Once on the cell surface, ps can easily be detected by staining with a fluorescent conjugate of annexin v, a protein that has a strong natural affinity for ps. In addition, the assay can be directly performed on live cells, without the need of fixation. The one-step staining procedure takes only 10 minutes. Both annexin v-fitc and sytox green dye emit green fluorescence that can be detected in the fl1 channel, freeing the other channels for the addition of other probes in multi-color labeling experiments. The annexin v-fitc apoptosis detection kit plus includes annexin v-fitc, sytox green dye, and binding buffer. The annexin v-fitc apoptosis detection kit plus is based on the observation that soon after initiating apoptosis, most cell types translocate the membrane phospholipid phosphatidylserine (ps) from the inner face of the plasma membrane to the cell surface. After staining a cell population with annexin v-fitc and sytox green dye in the provided binding buffer, apoptotic cells show green fluorescence, dead cells show a higher level of green fluorescence and live cells show little or no fluorescence. The sytox green dye is impermeant to live cells and apoptotic cells, but stains necrotic cells with intense green fluorescence by binding to cellular nucleic acids. ” Detects apoptotic, necrotic & -healthy cells within 10 min detection method- flow cytometry (ex = 488 nm -em = 530 nm). Species reactivity- mammaliankit size- convenient sizes (25, 100 and 400 assays)applications- annexin v-fitc kit includes annexin v-fitc for detecting apoptosis and also propidium iodide (pi) for detecting necrosis. “. These populations can easily be distinguished using a flow cytometry with the 488 nm line of an argon-ion laser for excitation.

 

BioVision Annexin V-EGFP Apoptosis Kit K104-25

BioVision Annexin V-EGFP Apoptosis Kit, K104-25

BioVision Annexin V-EGFP Apoptosis Kit, K104-25 - The kit can differentiate apoptosis vs necrosis when performing both annexin v-egfp and pi staining. “. In addition, the assay can be directly performed on live cells. Detection can be analyzed by flow cytometry or by fluorescence microscopy with a fitc filter. ” Detects apoptosis in live cells within 10 min. Egfp is brighter and more photo-stable than other fluorescent reagents. The one-step staining procedure takes only 10 minutes. -Flow cytometry (ex = 488 nm -em = 530 nm)and fluorescence microscopy -mammalian -25, 100, 400 -applications-detect early/middle stages of apoptosis -differentiate apoptosis from necrosis the annexin v-egfp apoptosis detection kit is based on the observation that soon after initiating apoptosis, most cell types translocate the membrane phospholipid phosphatidylserine (ps) from the inner face of the plasma membrane to the cell surface. Once on the cell surface, ps can be easily detected by staining with an enhanced green fluorescent protein (egfp) fusion of annexin v, a protein that has a strong natural affinity for ps.

 

BioVision Annexin V-Cy5 Apoptosis Kit K103-100

BioVision Annexin V-Cy5 Apoptosis Kit, K103-100

BioVision Annexin V-Cy5 Apoptosis Kit, K103-100 - ” Detects apoptosis within 10 min. “. Detection method- flow cytometry (ex = 649 nm -em = 670 nm) and fluorescence microscopyspecies reactivity- mammaliankit size- convenient sizes (25, 100, 400 assays) annexin v apoptosis detection kit is based on the observation that soon after initiating apoptosis, cells translocate the membrane phosphatidyl-serine (ps) from the inner face of the plasma membrane to the cell surface. Detection can be analyzed by flow cytometry or by fluorescence microscopy. Once on the cell surface, ps can be easily detected by staining with a fluorescent conjugate of annexin v, a protein that has a high affinity for ps. The one-step staining procedure takes only 10 minutes.

 

ApoAlert Annexin V-FITC Apoptosis Kit Takara Bio Cat No 630109

ApoAlert Annexin V-FITC Apoptosis Kit, (Takara Bio Cat. No. 630109)

ApoAlert Annexin V-FITC Apoptosis Kit, (Takara Bio Cat. No. 630109) - Complete kit for early detection of apoptotic cells based on binding to annexin v-fitc.

 

30067 - Dual Apoptosis kit with NucViewâ 488 and CF594 Annexin V 50 Assays - Fluorescent Probes NucView 488 Caspase-3 Substrate - Each

30067 – Dual Apoptosis kit with NucViewâ” 488 and CF594 Annexin V, 50 Assays – Fluorescent Probes, NucView 488 Caspase-3 Substrate – Each

30067 – Dual Apoptosis kit with NucViewâ” 488 and CF594 Annexin V, 50 Assays – Fluorescent Probes, NucView 488 Caspase-3 Substrate – Each - The substrate is non fluorescent until it is cleaved by caspase-3 to release the dye, which stains the nucleus with bright green fluorescence. Nucviewâ” 488 caspase-3 substrate has been used with many different immortalised and primary cell types in adherent, suspension and 3-d cultures. The substrate is offered in dmso, which facilities staining in some cells, in pbs for dmso sensitive cells, and in kits with caspase-3 inhibitor or other apoptosis probes. Nucviewâ” 488 caspase-3 substrate consists of the devd caspase-3 substrate peptide attached to a nucleic acid dye. -Real-time monitoring of caspase-3 activity -rapid, homogenous, no wash assay -image live cells or fix with formaldehyde after staining -for flow cytometry, fluorescence microscopy, or microplate reader using fitc settings nucviewâ” 488 caspase-3 substrate is a fluorescent probe for detection of caspase-3 activity in living cells.

 

BioVision Annexin V-PE-Cy5 Apoptosis Detection Kit K129-25

BioVision Annexin V-PE-Cy5 Apoptosis Detection Kit, K129-25

BioVision Annexin V-PE-Cy5 Apoptosis Detection Kit, K129-25 - Detection method- flow cytometry (ex = 488 nm -em = 670 nm) and fluorescence microscopy species reactivity- mammalian kit size- convenient sizes (25, 100, 400 assays)applications- detect early/middle stages of apoptosis -differentiate apoptosis from necrosis. Results can be analyzed by flow cytometry or fluorescence microscopy. ” Detects apoptosis in live cells within 10 min. “. Once on the cell surface, ps can be easily detected by staining with a fluorescent conjugate of annexin v, a protein that has a strong natural affinity for ps. The one-step staining procedure takes only 10 minutes. The annexin v-pe-cy5 apoptosis detection kit is based on the observation that soon after initiating apoptosis, most cell types translocate the membrane phospholipid phosphatidylserine (ps) from the inner face of the plasma membrane to the cell surface. In addition, the assay can be directly performed on live cells, without the need for fixation.

 

K203-25 - 25 Assays - Annexin V-PE Apoptosis Kit Plus BioVision - Each

K203-25 – 25 Assays – Annexin V-PE Apoptosis Kit Plus, BioVision – Each

K203-25 – 25 Assays – Annexin V-PE Apoptosis Kit Plus, BioVision – Each - 488 nm/em. 488 nm/em. “. After staining a cell population with annexin v-pe and sytox green dye in the provided binding buffer, apoptotic cells show red fluorescence, dead cells show green fluorescence and live cells show little or no fluorescence. The annexin v-pe apoptosis detection kit plus includes annexin v-pe, sytox green dye, and binding buffer. The annexin v-pe apoptosis detection kit plus is based on the observation that soon after initiating apoptosis, most cell types translocate the membrane phospholipid phosphatidylserine (ps) from the inner face of the plasma membrane to the cell surface. 530 nm) for sytox green dye and fl2 channel for annexin v-pe (ex. The one-step staining procedure takes only 10 minutes. 578 nm). The sytox green dye is impermeable to live cells and apoptotic cells, but stains necrotic cells with intense green fluorescence by binding to cellular nucleic acids. Sytox green dye is also included to control necrosis. Species reactivity- mammaliankit size- convenient sizes (25, 100 and 400 assays)applications- detecting apoptosis in living cells by flow cytometry or fluorescence microscopy. In addition, the assay can be directly performed on live cells, without the need of fixation. Once on the cell surface, ps can easily be detected by staining with a fluorescent conjugate of annexin v, a protein that has a strong natural affinity for ps. ” Detects apoptotic, necrotic & -healthy cells within 10 min detection method- flow cytometry using fl1 channel for sytox green dye (ex = 488 nm -em = 530 nm) and fl2 channel for annexin v-pe (ex = 488 nm -em = 578 nm). Pe shows brighter red fluorescence. These populations can easily be distinguished by fluorescence microscopy using fitc and pe filters or by flow cytometry using the fl1 channel (ex.

 

BioVision Annexin V-Cy5 Apoptosis Kit K103-400

BioVision Annexin V-Cy5 Apoptosis Kit, K103-400

BioVision Annexin V-Cy5 Apoptosis Kit, K103-400 - “. The one-step staining procedure takes only 10 minutes. Detection method- flow cytometry (ex = 649 nm -em = 670 nm) and fluorescence microscopyspecies reactivity- mammaliankit size- convenient sizes (25, 100, 400 assays) annexin v apoptosis detection kit is based on the observation that soon after initiating apoptosis, cells translocate the membrane phosphatidyl-serine (ps) from the inner face of the plasma membrane to the cell surface. ” Detects apoptosis within 10 min. Detection can be analyzed by flow cytometry or by fluorescence microscopy. Once on the cell surface, ps can be easily detected by staining with a fluorescent conjugate of annexin v, a protein that has a high affinity for ps.

 

BioVision Annexin V-FITC Apoptosis Kit K101-25

BioVision Annexin V-FITC Apoptosis Kit, K101-25

BioVision Annexin V-FITC Apoptosis Kit, K101-25 - Once on the cell surface, ps can be easily detected by staining with a fluorescent conjugate of annexin v, a protein that has a high affinity for ps. -Flow cytometry(ex = 488 nm -em = 530 nm) and fluorescence microscopy -mammalian -convenient sizes (25, 100, 400 assays) -detect early/middle stages of apoptosis -differentiate apoptosis from necrosis annexin v apoptosis detection kit is based on the observation that soon after initiating apoptosis, cells translocate the membrane phosphatidylserine (ps) from the inner face of the plasma membrane to the cell surface. ” Detects apoptosis and necrosis within 10 min. Detection can be analyzed by flow cytometry or by fluorescence microscopy. The one-step staining procedure takes only 10 minutes. “. The kit can differentiate apoptosis vs necrosis when performing both annexin v-fitc and pi staining.

 

BioVision Annexin V-FITC Apoptosis Kit K101-100

BioVision Annexin V-FITC Apoptosis Kit, K101-100

BioVision Annexin V-FITC Apoptosis Kit, K101-100 - The one-step staining procedure takes only 10 minutes. ” Detects apoptosis and necrosis within 10 min. -Flow cytometry(ex = 488 nm -em = 530 nm) and fluorescence microscopy -mammalian -convenient sizes (25, 100, 400 assays) -detect early/middle stages of apoptosis -differentiate apoptosis from necrosis annexin v apoptosis detection kit is based on the observation that soon after initiating apoptosis, cells translocate the membrane phosphatidylserine (ps) from the inner face of the plasma membrane to the cell surface. Detection can be analyzed by flow cytometry or by fluorescence microscopy. Once on the cell surface, ps can be easily detected by staining with a fluorescent conjugate of annexin v, a protein that has a high affinity for ps. The kit can differentiate apoptosis vs necrosis when performing both annexin v-fitc and pi staining. “.

 

BioVision Annexin V-Biotin Apoptosis Kit K109-100

BioVision Annexin V-Biotin Apoptosis Kit, K109-100

BioVision Annexin V-Biotin Apoptosis Kit, K109-100 - “. Once on the cell surface, ps can easily bind to biotin-conjugated annexin v, a protein that has a strong natural affinity for ps. The annexin v-biotin apoptosis detection kit is based on the observation that soon after initiating apoptosis, most cell types translocate the membrane phospholipid phosphatidylserine (ps) from the inner face of the plasma membrane to the cell surface. Annexin v-biotin can be detected in conjunction with conventional dye-staining using any streptavidine- or avidin-dye reagents, such as (strept)avidine-fluorescein, -peroxidase, -alkaline phosphatase (ap), and -β-gal, etc. ” Detects apoptosis by facs or fl detection method- flow cytometry (ex = 488 nm -em = 530 nm) using and fluorescence microscopy species reactivity- mammalian kit size-convenient sizes (25, 100, 400 assays)applications- detect early/middle stages of apoptosis -differentiate apoptosis from necrosis.

 

K203-400 - 400 Assays - Annexin V-PE Apoptosis Kit Plus BioVision - Each

K203-400 – 400 Assays – Annexin V-PE Apoptosis Kit Plus, BioVision – Each

K203-400 – 400 Assays – Annexin V-PE Apoptosis Kit Plus, BioVision – Each - 488 nm/em. After staining a cell population with annexin v-pe and sytox green dye in the provided binding buffer, apoptotic cells show red fluorescence, dead cells show green fluorescence and live cells show little or no fluorescence. The annexin v-pe apoptosis detection kit plus is based on the observation that soon after initiating apoptosis, most cell types translocate the membrane phospholipid phosphatidylserine (ps) from the inner face of the plasma membrane to the cell surface. Species reactivity- mammaliankit size- convenient sizes (25, 100 and 400 assays)applications- detecting apoptosis in living cells by flow cytometry or fluorescence microscopy. 578 nm). The one-step staining procedure takes only 10 minutes. These populations can easily be distinguished by fluorescence microscopy using fitc and pe filters or by flow cytometry using the fl1 channel (ex. “. Pe shows brighter red fluorescence. ” Detects apoptotic, necrotic & -healthy cells within 10 min detection method- flow cytometry using fl1 channel for sytox green dye (ex = 488 nm -em = 530 nm) and fl2 channel for annexin v-pe (ex = 488 nm -em = 578 nm). 488 nm/em. The annexin v-pe apoptosis detection kit plus includes annexin v-pe, sytox green dye, and binding buffer. In addition, the assay can be directly performed on live cells, without the need of fixation. Once on the cell surface, ps can easily be detected by staining with a fluorescent conjugate of annexin v, a protein that has a strong natural affinity for ps. The sytox green dye is impermeable to live cells and apoptotic cells, but stains necrotic cells with intense green fluorescence by binding to cellular nucleic acids. Sytox green dye is also included to control necrosis. 530 nm) for sytox green dye and fl2 channel for annexin v-pe (ex.





We are a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for us to earn fees by linking to Amazon.com and affiliated sites.